This machine consists of control cabin and host, advanced technology and parts design and manufacture are introduced from Japan. It has selective magnetization such as round, vertical and combined magnetization. Semi-automatic operation is controlled by PLC (automatic step: clamp – spray –magnetization – rotation –demagnetization – loose). Manual operation is also valid.
This machine is equipped with E-40 UV light from Japan, which has super high intensity. So it is possible to take advantage of fluorescent magnetic particle flaw detectiion

?

Power

AC 50Hz, 3-phase, 4-line, L1/L3 100A(instantaneous load), L2/N 10A (instantaneous load).

Compressed air

0.35~0.6MPa

Max instantaneous input power

30KVA

Round magnetization curren

0~2000A(RMS) non-graded adjustment.

Vertical magnetization:

DC yoke type, magnetomotive force: 0~28800(AT), non-graded adjustment.

Automatic demagnetization

 

AC/DC damping voltage rate: non-graded adjustment.DC polarity alternating frequency: 0.5~5HZ adjustable. AC demagnetization damping voltage may be applied separately or concurrently. Demagnetization: DC damping voltage with its polarity alternating.

Clamp distance:

0~900mm adjustable

The height of central clamp:

220mm

UV light intensity of E-40:

At 400mm, under the filter center:≥14000m W/cm2  

Dimension

Host: 1760′700′2100, control cabin: 600′555′1760(mm)

Customer example:中国第一汽车集团公司底盘厂


SMT-CEW/D-3000

SMT-CEW/D-3000 Mobile/Immobile Magnetic Particle Flaw Detection Machine

·This machine is equipped with advanced 303D magnetization power source and E-40 black light. Magnetization AC current or half wave DC current may be selected to carry our round, vertical magnetization and fluorescent magnetic particle flaw detection with high intensity of UV light. Digital display of magnetization current with upper and lower limit preset. It also has demagnetization function.
Magnetization power source with bottom roller may be pulled out, which can carry out flaw detection on the large scale work-pieces with 触头 method and 烧电缆 method. This machine is suitable to these manufactures which have small quantity of work-piece with wide variety of type and size.
·Power supply: AC 220V.50Hz, 80A,single phase.
·Magnetization current output: AC 0-3000A(peak to peak)
·Demagnetization: AC 0-3000A(peak to peak)
·Rate of load: 10%
·Maximum distance between clamp: 0-800mm
·Coil of magnetization: 8 turns, diameter: 300mm, movable.
·Liquid tank volume: 25 liter
·Intensity of UV light: at 380mm under the filter:³14000muw/cm2.


SMT-CEW-4000

SMT-CEW-4000 Series AC/DC Magnetic Particle Flaw Detection Machine

·Vertical Magnetization is performed by closed loop yoke and auxiliary coil. It is suitable to work-piece in comp1ex shape such as shaft etc. Its semiautomatic operation function is under PLC control. Operator may adjust parameters on control panel, high intensity UV light mounting is available if required.
·Power supply: AC 380V, 50Hz, 3 phases, and 4 lines
·Maximum instantaneous input power: 32KVA
·Round magnetic current (AC): 0-4000A (RMS) non-graded adjustment.
·Vertical magnetic DC current: yoke only, 0-28000 AT (current:0-l2.5A)
·To use Yoke and coil simutaneously: 0-30000 AT (current:0-10A)
·Demagnetization on the machine: Round AC damping Voltage demagnetization voltage decreasing: non-graded. Vertical DC demagnetization: voltage decreasing with change in polarity, rate of decreasing voltage: non-graded, frequency of change in polarity is adjustable.
·Distance between clamps: 0-l250mm, adjustable.
·Central height of magnetizing: 285mm
·Diameter of magnetization c1amp: 170mm
·Inner diameter of movable coil: 300mm
·Rate of load: 20%
·Liquid tank volume:³25L

 


JE-303D

JE-303D Magnetization Power Source (special for magnetic particle f1aw detection)

·Major part and component are imported from Japan
·Magnetization current adjustment is controlled by thyristor module and printed digital
board that are imported from Japan and has non-graded regulator function which is reliable and easy for use.
·Digital explicit indication of magnetization current by the most advanced Omron intellectual faculties meter imported from Japan
·In order to ensure quality of flaw detection, upper and lower limit of magnetization
current setting is necessary according to requirement. Alarm will be triggered on if
beyond the limit.
·Less volume and weight: reliable and convenient for mobile operation
·Magnetization of work-piece may be performed in various way so as to detect and find
defect in different direction.
·Mobile type of magnetic particle flaw detection machine, current peak value: AC/DC
3000A, digital indication, AC/DC alternation without replacing plug of large current.

 

MP-A3

MP-A3 AC Handy Magna

·Made in South Korea
·Power: AC 220V/50Hz
·Polarity distance: l37.5mm
·Lifting force: >4.53Kg(10LB)

1 2 3 4 5 6 下一页