SMT-CEW-1000Z AC/DC Semi-automatic fluorescent magnetic particle flaw detection machine

· Round magnetization current: AC 0-1000A

· Vertical magnetization electromagnetic force: DC 0- 28000NA(magnetomotive force).

· Maximum distance between two clamps: 500mm

· MITSUBISHI PLC controller from Japan, 2 sets of automatic control program: mode: clampingspraymagnetizationunclamping
              clampingspraymagnetizationdemagnetizationunclamping· E-40 UV light from Japan, which provides super intensify UV-A safe light allowing to work with curtain open. Intensity at 400mm under the filter:³14000muw/cm2
·Thyrister from Japan,SMC cylinder from Japan, spray global value from Italy etc.
· New and smart, the machine is covered by stainless steel, which is durable; its stainless steel sliding liquid tank is convenient for liquid replacement.

· Air-cooling, system is designed for electrical control box, so it may work continuously in high frequency.

·It is optional to select electric rotation console and AC coil demagnetization machine (working frequency£6seconds/work-piece)

 

 

 

 
 

 

SMT-CEW-2000Z AC/DC Semi-automatic fluorescent magnetic particle flaw detection machine

·Round magnetization current: AC 0-2000A)

·Vertical magnetization electromotive force: DC 0-28000NA(magnetomotive force)Distance between two clamps: 900mm
·MISUBISHI PLC controller from Japan, 2 sets of automatic control program

  mode :Clampingspraymagnetizationrotation
(for inspection)demagnetizationunclamping
clampingsprayingmagnetizationrotation(for inspection) unclamping

·4 parameter dates of time of PLC may be direct input on the panel of controller without programming device.
· Rotation of 2 clamps are driven by motor, it can be continuous or in small step. Its direction: clockwise or anti-clockwise or in small step. Its direction: clockwise or anti-clockwise.
·
E-40 UV-light, which provides super intensity UV-A safe light allowing to work with curtain open. Intensity at 400mm under the filter:³14000muw/cm2.
· Cantilever type controller from Germany, new and nice appearance, easy for operation.

· Thyrister form Japan, SMC cylinder from Japan, spray global valve from Italy etc. · Machine is coated with automobile metal paint, which is durable and shiny

·  New method of stir with horizontal pump can avoid magnetic particles precipitation, Stainless steel sliding liquid tank is convenient to replace liquid.

 


 

 

---SMT-XXG系列携带式变频气绝缘波纹陶瓷管X射线探伤机---

Feature

Digital indication,isolation control, automatic protection and modular control circuit.

Advanced technology of frequency keying that ensures stable tube current.

Proper heat sink structure, continuous working load ratio:1/1.

○ Automatic warm-up, quick to be ready fro operation

○ International universal fast plug combination

○ Excessive voltage, heat , current and non-current protection by circuit.

○ Corresponding error message and operation state display on screen

○ Automatic delay function and electronic switch lock for high voltage so as to secure safety, it is suitable for fieldwork.

○ Automatic time counting continuously to avoid waste of film due to exposure interruption

Major technical parameters:

  model\item

SMT-XXG-1605

SMT-XXG-2005

SMT-XXG-2505

SMT-XXG-3005

in

power(V)

  198~242        ( 50HZ

Capacity

  1.6 KVA

  1.8 KVA

2.5 KVA

  3.0 KVA

out

Tube voltage)

60~160

  100~200

 150~250

  170~300

tube current

  5 mA

   focus (mm)

2.0×2.0

  1.5×1.5

  2.0×2.0

  2.5×2.5

  Radiation angle(degree)

  45+5   directional

Penetration(mm)Fe

     20

     29

    38

50

   sensitivity

  ≤1.5 %

  ≤1.8 %

  Operation mode

working interval (without power cut off): 1/1,5min/5min

control

Dimension(mm)

360×300×145

Weight(Kg)

12

Dimension(mm)

225×225×560

270×270×585

320×320×620

340×340×650

Weight(Kg)

    18.5

     20

    32

     40

Ambient work temperature

  -30~+40

 

---SMT-UTZ-1 Diesel Engine Ultrasonic Inspection System ---

1. Application:
Aluminum alloy piston of diesel engine cylinder with steel ring
whose diameter is from 90 to 150mm.

2. Test method

work-piece merges partially below water, ultrasonic wave penetration, three transducers, two receivers, one transmitter. Work-piece rotation is driven by step motor, quality evaluation is based on wave strength received by R1and R2 after penetration. Poston quality is good if the strength is above threshold value, whereas it is poor.

3. Function
Pentium PC with keyboard, color monitor and HD.
Operating system: Windows 2000/XP.
Automatic computing and controlling by special software. Each test result is displayed on screen according to input acceptance level.
Test result data is displayed on screen for each tested piston: a single defect size, distance between two defects, the size of area overlapped by two layers, total defect area calculation(0.1% resolution, 360o/1000).
The above data corresponding to flaw are in percentage.

User may adopt and use standard for enterprise and input data directly from user graphic interface of PC.

Work-piece is manually loaded or unloaded, testing period is about 20 seconds per each, 150 pieces per hours. Work-piece rotation and test is automatically carried out.

Test result may be stored on hard-disk and printed out or transmitted.

In automatic operation mode, ultrasonic testing device is calibrated automatically.

Protection device:
Light and electric sensor protection when loading or unloading

Automatic startup with two switches.

??

---Fuji FCR Dynamix-4--

The era of digital image technology of radiation test has come, it is known just like? a digital camera, which has no conventional film. Fuji FCR represents the latest technology of international digital RT. Marktec is its exclusive representative in China.

System feature:

  1. Conventional RT film is replaced by IP(image paper) which is soft, bendable, less weight, reusable and easy to handle.
  1. Sensitometry of IP is ten time greater than IX 100# film, exposure time can be reduced, which has high work efficiency.
  1. Four digits (10,000 times) tolerance range, so 透照 condition may be less confined.
  1. Good image is obtained through a EDR reading process, which has automatic sensitivity adjustment.
  1. High brightness of pixel (1600 × 1200, horizontal × vertical). Inage and information are displayed on high resolution monochromic CRT, explicit image on it just like X-ray conventional film.
  1. Due to digital image, image processing, adjustment and remote?evaluation may be possible via PC network.
  1. Improve work condition of X-ray test, no dark-room is required.